İçeriğe atla
ORANSAL VALF GPV-130 - GNR Endüstriyel
Oransal Valf

ORANSAL VALF GPV-130

ModelGPV-130

GPV 130 directional control valve group is commonly used for excavators, front loaders, cranes and backhoe loaders, vessels which need proportional control.

Operating pressure
Port P continuous 1)
Bu ürün için teklif alın

Hafta içi 08:30 – 18:30 arası aynı gün dönüş

Teknik veri sayfası

Değerler üretici katalog verisinden birebir aktarılmıştır. Port konfigürasyonu, sürgü tipi ve yardımcı valf seçenekleri sipariş aşamasında belirlenir.

Konfigürasyon desteği alın
Teknik özellikler 1
Max. pressure
Port P continuous 1)350 bar[5075 psi]
Port P intermittent 5)
400 bar[5800 psi]
Port A/B continuous
350 bar[5075 psi]
Port A/B intermittent
420 bar[6090 psi]
Port T, static/dynamic
25/40 bar[365/580 psi]
Oil flow rated
Port P 3) 4)140/230 l/min.[37/61 US gal/min]
Port A/B, with press. comp.2)
100 l/min.[26.4 US gal/min]
Port A/B, without press. comp.
130 l/min.[34 US gal/min]
Spool travel, standard
± 7 mm[±0.28 in]
Spool travel, float position
Proportional range± 4.8 mm[±0.19 in]
Float position
± 8 mm[±0.32 in]
Dead band, flow control spools
Standard± 1.5 mm[±0.06 in]
Linear characteristic
± 0.8 mm[±0.03 in]
Max. internal leakage at 100 bar [1450 psi] and 21mm2/s[102 SUS]
A/B ® T without shock valve20 cm3/min.[1.85 in3/min]
A/B ® T with shock valve
25 cm3/min.[2.15 in3/min]
Oil temperature (inlet temperature)
Recommended temperature30 ® 60 °C[86 ® 140 °F]
Min. temperature
-30 °C[-22 °F]
Max. temperature
+90 °C[194 °F]
Ambient temperature
-30 ® 60 °C[-22 ® 140 °F]
Oil viscosity
Operating range12 - 75 mm2/s[65 - 347 SUS]
Min. viscosity
4 mm2/s[39 SUS]
Max. viscosity
460 mm2/s[2128 SUS]
Filtration (See chapter Filtration)
Max. contamination(ISO 4406)23/19/1623/19/16
Oil consumption in pilot oil pressure reduction valve
5 l/min.[0.13 US gal/min]
Teknik özellikler 2
Product
Maximum continuous P-port pressure
GPV 130 with PVS
300 bar [4351 psi]
GPV 130 with PVSI
350 bar [5076 psi]